Hi all,
I use Karl Suss wafer bonder and I have some problems for bonding, using
patterned polymer, two wafers : Si/Glass.
The polymer thickness is about 10 microns and the problem it's all about
the thickness of my 300µm Pyrex wafers (+/- 25µm) (standard product).
So when I apply the pressure on the pyrex wafer I'm not able to bonding
perfectly and with a good uniformity in the whole wafer.
I'd like to know if anybody has the same kind of problem and a possible
solution.
Thanks.


*********************************************************