A MEMS Clearinghouse® and information portal
for the MEMS and Nanotechnology community
RegisterSign-In
MEMSnet Home About Us What is MEMS? Beginner's Guide Discussion Groups Advertise Here
News
MEMSnet Home: MEMS-Talk: wire bonding of MUMPs device
wire bonding of MUMPs device
2003-11-07
yong zhu
2003-11-07
Mighty Platypus
wire bonding of MUMPs device
yong zhu
2003-11-07
Dear All,

My device is a thermal in-plane actuator made by MUMPs
process. It moves mainly forward in-plane under
applied voltage though a little downwards motion
occurs. However, the weird thing is that after the
wire bonding, the device only moves down. I have
tested a bunch of devices, which all show this
behavior. I donnot think stiction is the reason
because stiction is also existing before the wire
bonding. I am curious what's the cause and how to
avoid this.

Many thanks,

Yong

__________________________________
Do you Yahoo!?
Protect your identity with Yahoo! Mail AddressGuard
http://antispam.yahoo.com/whatsnewfree