Hi Jeff,
How thick are your Ti strips ? If it is too thin it may look completely
diluted in the crystal.
Regards,
Bruno Wacogne
At 15:03 01/09/2004 -0400, you wrote:
>Hello,
>
>I am trying to diffuse Ti strips into Lithium Niobate. The strips run
>from approximately 3 -10 um. After diffusion (which I have run
>different permutations ranging from 1-9h and 900-1050C) in a wet
>nitrogen environment the waveguides completely disappear. I know that
>the index delta should be approximately .01 so they should be difficult
>to see, but I can't seem to see anything at all. I was wondering if
>anyone has had this problem before or can help me find a solution. Thanks.
>
>Jeff Price
>Research Assistant, University of Delaware
>price@ee.udel.edu
>
>_______________________________________________
>MEMS-talk@memsnet.org mailing list: to unsubscribe or change your list
>options, visit http://mail.mems-exchange.org/mailman/listinfo/mems-talk
>Hosted by the MEMS Exchange, providers of MEMS processing services.
>Visit us at http://www.memsnet.org/
>
***********************************************
* *
* Bruno Wacogne *
* Laboratoire d'Optique P.M. Duffieux *
* Faculté des Sciences et des Techniques *
* Route de Gray *
* 25030 Besançon cedex *
* *
* tel (++33) 3 81 66 64 25 *
* fax (++33) 3 81 66 64 23 *
* mel bruno.wacogne@univ-fcomte.fr *
* *
* http://imfc.univ-fcomte.fr/lopmd/index.html *
* http://imfc.univ-fcomte.fr/ *
* *
***********************************************