Does your mask make a good contact with the samples? I had this problem when
my samples had edge bead. It sounds like also underexposed.
Patrick Poissant
___________________________________________________
M.A.Sc. Student
Dept. of Electrical Engineering
Université de Sherbrooke
Sherbrooke (Québec) J1K 2R1
CANADA
patrick.poissant@usherbrooke.ca
Sherbrooke Microelectronics Research Group
www.gel.usherb.ca/gms
Anyone who has never made a mistake has never tried anything new - Albert
Einstein
----- Original Message -----
From: "suscarl"
To:
Sent: Wednesday, September 08, 2004 11:15 AM
Subject: [mems-talk] unwanted tapering of SU-8 structures
> Need advice from SU-8 experts:
> I have 30um width by 55um height SU-8 2035 lines. Somehow, after 35s
exposure time and post-bake of 95oC for 20min, the resulting structures are
tapered with bottom 60um width and top 40um width. Can anyone offer possible
solutions to troubleshoot the problem?
>