Is there any UV filter installed in the lamp house?

Exposure of SU-8 should not be done with UV light less than 340nm
wavelength.

Shorter wavelengths would create cracks in the resist layer and cause
problems regarding sidewall angle.


i-line exposure is recommended by resist vendor.

Best Regards, Norbert Nodes