May have overheated the magnetron and loose the magnetic field strength of
of your permenant magnets
-----Original Message-----
From: [email protected] [mailto:[email protected]]
On Behalf Of saravan kallempudi
Sent: Thursday, August 02, 2007 6:55 AM
To: [email protected]
Subject: [mems-talk] Problem with DC Sputter
Dear Members,
I have a problem with my DC sputter. We used to sputter Nickel but we have
strange problem now having plasma inside chamber but unable to sputter
nickel. I thought of target poisoning and I cleaned the target with
Nitricacid and then also I was not able to move forward. Can anyone suggest
me in this!