MEMSnet Home: MEMS-Talk: SU-8 spinning problems
SU-8 spinning problems
2002-03-15
Glen Landry
2002-03-15
[email protected]
2002-03-15
CLIF HAMEL
2002-03-15
Vic Kley
2002-03-15
Henry Yang
2002-03-15
[email protected]
wafer level vacuum packaging
2002-03-15
Krishna Kashyap
2002-03-15
CLIF HAMEL
SU-8 spinning problems
Henry Yang
2002-03-15
Pour the SU-8 2050 directly from the bottle. Forget the pipette.

Henry Yang

Glen Landry @memsnet.org on 03/15/2002 05:24:24
AM

Please respond to [email protected]

Sent by:    [email protected]


To:    [email protected]
cc:
Subject:    [mems-talk] SU-8 spinning problems



 I have a problem spinning SU-8 2050 photoresist (Microchem corp). When
I place the required amount on my 2" silicon wafer and spin, it does not
spread uniformly. Instead it all goes to one side (if it is not exactly
centered) or it spreads out in a starfish pattern, leaving large portions
of the wafer uncovered.
 I have tried manually spreading the SU-8 across the wafer, with my
pipette, but this introduces bubbles. It was also suggested to tilt the
wafer to get the SU-8 to spread, or to sit it on a table. Neither of these
suggestions worked, since the SU-8 2050 is so viscous and it takes so long
to spread with gravity, a skin forms on the SU-8 before it spreads.

Does anyone have suggestions?

Glen Landry
_______________________________________________
[email protected] mailing list: to unsubscribe or change your list
options, visit http://mail.mems-exchange.org/mailman/listinfo/mems-talk
Hosted by the MEMS Exchange, providers of MEMS processing services.